CXR 4 Multi-Slice CT – Fixed unit CT For Sale – $35,000
Used Hitachi 4 Slice CT Scanner for Sale in Good Working Condition –
Coming out of hospital Oct 30 – ready now for inspection –
buyer assumes responsibility to remove item and disassemble.
Item sold refurbished by Hitachi in 2007 – medical item coming
up on lease in Phoenix Arizona.
BUY 4 Slice CT Scan
Contact us at 858-731-7278 getinfo@san.rr.com
Se Habla Espanol Gloria 858-922-6862 g1medinfo@gmail.com
Used Hitachi 4 Slice CT CONFIGURATION OPTIONS
CT scanner mode (CONFIGURATION OPTIONS) Multislice
CT angiography package (CONFIGURATION OPTIONS) Included standard
3D Image processing and display package (CONFIGURATION OPTIONS)
Included standard
Additional clinical applications (CONFIGURATION OPTIONS)
MIP, MPR, Direct Cine Display, LungCAD, CT Colonography optional
TECHNICAL SPECIFICATIONS
Dynamic scan rate (TECHNICAL SPECIFICATIONS)
300 slice/min
Image reconstruction time – 2D [Seconds] (TECHNICAL SPECIFICATIONS)
.2 seconds
FOV (Min, Max) (TECHNICAL SPECIFICATIONS)
2-50 cm
Automated dosage control (TECHNICAL SPECIFICATIONS)
Yes
High contrast spatial resolution at 0% MTF (TECHNICAL SPECIFICATIONS)
14.31 lp/cm
High contrast spatial resolution at 50% MTF (TECHNICAL SPECIFICATIONS)
3.51 lp/cm
Rotation Speed Range (TECHNICAL SPECIFICATIONS)
.8 – 3.0 Min sec. – Max sec. per rotation, increments
X-Ray generator kVp range
100, 120, 130
Gantry diameter (TECHNICAL SPECIFICATIONS)
70 cm
On-line image storage capacity (TECHNICAL SPECIFICATIONS)
80GB for 20,000 Images
Table movement range cm, vertically / longitudinally (TECHNICAL SPECIFICATIONS)
61/262.5
Table scanning range (TECHNICAL SPECIFICATIONS)
147 cm
Table weight limit [lbs] (TECHNICAL SPECIFICATIONS)
400
Minimum room size requirements (Length x Width x Height) (TECHNICAL SPECIFICATIONS)
15 x 11
Power requirements (VAC, Amps)
208, 3 phrase, 75 KVA
Heat output (TECHNICAL SPECIFICATIONS)
12, 800 BTU
INTERFACE CAPABILITY AND SPECIFICATION
DICOM query/retrieve class user/provider (INTERFACE CAPABILITY AND SPECIFICATION)
Yes
DICOM storage class user/provider
Yes
DICOM storage commit compliant (INTERFACE CAPABILITY AND SPECIFICATION)
Yes
DICOM print class user/provider (INTERFACE CAPABILITY AND SPECIFICATION)
Yes
DICOM Conformance URL (INTERFACE CAPABILITY AND SPECIFICATION) 3.0
MODEL
CXR4
PERFORMANCE
0% mtf, lp/cm (High-contrast spatial resolution)
14.31
50% mtf, lp/cm (PERFORMANCE)
3.51
Slice sensitivity profile
Low-contrast resolution, mm at % at ≤20 mGy (2 rads) (Slice sensitivity profile)
3 mm at 0.25%
Type (CONFIGURATION)
Multislice
# of slices (X-ray tube anode)
4
POWER NEEDED
208 V, 3-phase, 75 kVA
X-RAY TUBE
Heat storage, MHU (X-RAY TUBE)
5
Heat dissipation rate, kHU/min (X-RAY TUBE)
750
Tube cooling (X-ray tube anode)
Oil/air
Tube focal spots, mm (X-RAY TUBE)
0.7 x 0.8, 1.2 x 1.4
Expected tube life, scan sec (& calendar) (X-RAY TUBE)
120,000 rotations
Maximum ma (X-ray tube anode)
250
Maximum scan time at maximum ma, sec (X-ray tube anode)
30 at 300, 80 at 250, 100 at 200
IMAGE RECONSTRUCTION
Cpu (NETWORK/DATABASE)
Dual CPU
Scan fovs, cm (IMAGE PROCESSING)
2-50, 1 mm steps
Reconstruction matrices (IMAGE RECONSTRUCTION)
512 x 512
Per slice, sec (Reconstruction time)
0.2
No. of online images (IMAGE STORAGE)
20000
Archive (IMAGE STORAGE)
DVD
CLINICAL APPLICATIONS AND FUNCTIONALITY
Coronary artery calcification scoring (CLINICAL APPLICATIONS AND FUNCTIONALITY)
Optional
Lung nodule assisted reading (Myocardial evaluation)
Optional
Virtual colonoscopy assisted reading (Myocardial evaluation)
Optional
Other (ROTORS)
General imaging, pulmonary, vasculature
DICOM (GANTRY)
Yes
RADIATION DOSE
Dose modulation technique (X-ray tube anode)
Adaptive mA
TABLE FEATURES
Range of movement
Vertical, cm (Range of movement)
42-100
Longitudinal, cm (Range of movement)
186
Scanning range,cm (Range of movement)
150
Max load capacity (accuracy, mm), without restrictions, kg (Range of movement)
180 (not specified)
GANTRY
Gantry angle deg (GANTRY)
±25
Gantry size, hxwxd,cm (GANTRY)
198 x 182 x 84
Gantry weight, kg (GANTRY)
1480
Gantry opening, cm (GANTRY)
70
Scan localizer (GANTRY) Laser
GENERATOR
kW output (GENERATOR) 42
Kvp range (GENERATOR) 100
Ma range (IMAGING SYSTEM) 25
IMAGE PROCESSING (MAXIMUM DISPLAY)
Standard or optional (IMAGE PROCESSING) Standard
Dicom 3-d image export (IMAGE PROCESSING) Yes
RECOMMENDED ROOM SIZE, m² (IMAGE PROCESSING) 28
DETECTOR (SCATTERED LIGHT)
Total detector width, z-axis, mm (DETECTOR) 20
Optional min slice width, mm (DETECTOR)
Standard Rotation times, sec, 360° (DETECTOR) 0.8, 1, 1.5, 2, 3
Optional min rotation time, sec (DETECTOR)
OTHER ATTRIBUTES (Interference compensation)
Gantry slice thickness: 0.75, 1.25, 1.5, 2.5, 3.75, 5, 7.5, and 10 mm.
FDA CLEARANCE (Interference compensation) Yes
Escáner CT usados para la venta / 4 slice CT Hitachi CRX4
CT Scan unitario fijado en buenas condiciones de trabajo
Equipo CT usados en venta
Used CT Scanner for sale / 4 slice CT Hitachi CRX4
CT Scan Fixed Unit in good working condition
Used CT Equipment for Sale
BUY 4 Slice CT Scan
Contact us at 858-731-7278 getinfo@san.rr.com
Se Habla Espanol Gloria 858-922-6862 g1medinfo@gmail.com